HEX
Server: LiteSpeed
System: Linux premium179.web-hosting.com 4.18.0-553.50.1.lve.el8.x86_64 #1 SMP Thu Apr 17 19:10:24 UTC 2025 x86_64
User: spytydfj (1022)
PHP: 8.1.33
Disabled: NONE
Upload Files
File: /home/spytydfj/mail/new/1739919702.M145734P96206.premium179.web-hosting.com,S=7887,W=8055
Return-Path: <>
Delivered-To: spytydfj@premium179.web-hosting.com
Received: from premium179.web-hosting.com
	by premium179.web-hosting.com with LMTP
	id cB7ABlYRtWfOdwEAYWq+3Q
	(envelope-from <>)
	for <spytydfj@premium179.web-hosting.com>; Tue, 18 Feb 2025 18:01:42 -0500
Return-path: <>
Envelope-to: spytydfj@premium179.web-hosting.com
Delivery-date: Tue, 18 Feb 2025 18:01:42 -0500
Received: from mailnull by premium179.web-hosting.com with local (Exim 4.96.2)
	id 1tkWb0-000Qjo-05
	for spytydfj@premium179.web-hosting.com;
	Tue, 18 Feb 2025 18:01:42 -0500
X-Failed-Recipients: admin@test2.spytamil.com
Auto-Submitted: auto-replied
From: Mail Delivery System <Mailer-Daemon@premium179.web-hosting.com>
To: spytydfj@premium179.web-hosting.com
References: <RvRbWC79TEkT6UJQHOGBX28hYvxVzvoC0RTsyR40ig@thamilkathir.com>
Content-Type: multipart/report; report-type=delivery-status; boundary=1739919702-eximdsn-1216622677
MIME-Version: 1.0
Subject: Mail delivery failed: returning message to sender
Message-Id: <E1tkWb0-000Qjo-05@premium179.web-hosting.com>
Date: Tue, 18 Feb 2025 18:01:42 -0500

--1739919702-eximdsn-1216622677
Content-type: text/plain; charset=us-ascii

This message was created automatically by mail delivery software.

A message that you sent could not be delivered to one or more of its
recipients. This is a permanent error. The following address(es) failed:

  admin@test2.spytamil.com
    No Such User Here

--1739919702-eximdsn-1216622677
Content-type: message/delivery-status

Reporting-MTA: dns; premium179.web-hosting.com

Action: failed
Final-Recipient: rfc822;admin@test2.spytamil.com
Status: 5.0.0

--1739919702-eximdsn-1216622677
Content-type: message/rfc822

Return-path: <spytydfj@premium179.web-hosting.com>
Received: from spytydfj by premium179.web-hosting.com with local (Exim 4.96.2)
	(envelope-from <spytydfj@premium179.web-hosting.com>)
	id 1tkWaz-000Qja-2I
	for admin@test2.spytamil.com;
	Tue, 18 Feb 2025 18:01:41 -0500
To: admin@test2.spytamil.com
Subject: =?us-ascii?Q?Thamil_Kathir_"How_to_eliminate_machine_tool_mi?=
 =?us-ascii?Q?lling_machine_rotor_vibration=3F"?=
Date: Tue, 18 Feb 2025 23:01:41 +0000
From: Thamil Kathir <admin@test2.spytamil.com>
Reply-To: taanakeif@gazeta.pl
Message-ID: <RvRbWC79TEkT6UJQHOGBX28hYvxVzvoC0RTsyR40ig@thamilkathir.com>
X-Mailer: PHPMailer 6.9.2 (https://github.com/PHPMailer/PHPMailer)
MIME-Version: 1.0
Content-Type: text/plain; charset=UTF-8
Sender:  <spytydfj@premium179.web-hosting.com>

From: EQiblycix taanakeif@gazeta.pl
Subject: How to eliminate machine tool milling machine rotor vibration?

Message Body:
<h2>  Detailed Rotor Balancing Process  </h2> 
 
<h3>  Getting the Equipment Ready  </h3> 
<ul> 
<li>  accelerometers, laser rpm sensor, mounting stand, software application, and additional tools.  </li> 
<li>   Set up the instrument and connect it to your computer via USB. Verify that the software is correctly installed.    </li> 
</ul> 
 
<h3>  Sensor Installation  </h3> 
<ul> 
<li>   Mount the vibration transducers securely on the machine's housing where vibrations are most pronounced, typically near the bearings.    </li> 
<li>   Position the laser tachometer (phase angle sensor) so that it is aimed at the rotor. Attach reflective tape to the rotor for accurate phase angle reading.    </li> 
</ul> 
 
<h3> Software Startup   </h3> 
<ul> 
<li>   Launch the Balanset software on your computer.    </li> 
<li>  Configure the software for either single-plane or two-plane balancing, based on the rotor's characteristics and the desired outcome.  </li> 
</ul> 
 
<h3>  Taking Baseline Vibration Readings  </h3> 
<a href="https://vibromera.eu/wp-content/uploads/2024/11/2-Camera_01.png" target="_blank"> 
<img src="https://vibromera.eu/wp-content/uploads/2024/11/2-Camera_01.png" alt="2-Camera_01" style="width: 50%; display: block; margin-bottom: 10px;"> 
</a> 
<ul> 
<li>   Operate the rotor at its intended working speed.  </li> 
<li>   The application will acquire data on vibration magnitude, rotational velocity, and phase angle to determine the initial imbalance state.  </li> 
</ul> 
 
<h3> Trial Weight Installation   </h3> 
<a href="https://vibromera.eu/wp-content/uploads/2024/11/3-Camera-2_01.png" target="_blank"> 
<img src="https://vibromera.eu/wp-content/uploads/2024/11/3-Camera-2_01.png" alt="3-Camera-2_01" style="width: 50%; display: block; margin-bottom: 10px;"> 
</a> 
<ul> 
<li>  Halt the rotation and mount a test weight at a designated position on the rotor, with the weight's value entered into the software (usually in grams).  </li> 
<li>  Run the rotor again, allowing the software to measure the effects of the trial weight on vibration and phase.  </li> 
</ul> 
<a href="https://vibromera.eu/wp-content/uploads/2024/11/5-Camera_01.png" target="_blank"> 
<img src="https://vibromera.eu/wp-content/uploads/2024/11/5-Camera_01.png" alt="5-Camera_01" style="width: 50%; display: block; margin-bottom: 10px;"> 
</a> 
 
 
<h3> Calculating the Correction Weight   </h3> 
<ul> 
<li>  Using the acquired measurements, the program automatically determines the required corrective weight's mass and angular position.  </li> 
<li>   These parameters are displayed on the screen as numerical data and graphs.    </li> 
</ul> 
<a href="https://vibromera.eu/wp-content/uploads/2024/02/Bs1ManualEngV156-May2023-10448629.png" target="_blank"> 
<img src="https://vibromera.eu/wp-content/uploads/2024/02/Bs1ManualEngV156-May2023-10448629.png" alt="Bs1 Manual" style="width: 30%; display: block; margin-bottom: 10px;"> 
</a> 
 
<h3> Attaching the Corrective Mass  </h3> 
<ul> 
<li>  Attach the computed compensating weight to the rotor as indicated by the software's output.  </li> 
<li>   If necessary, perform intermediate checks to verify that the imbalance is being reduced.    </li> 
</ul> 
<a href="https://vibromera.eu/wp-content/uploads/2024/11/1-Camera-2_01.png" target="_blank"> 
<img src="https://vibromera.eu/wp-content/uploads/2024/11/1-Camera-2_01.png" alt="1-Camera-2_01" style="width: 50%; display: block; margin-bottom: 10px;"> 
</a> 
 
<h3>  Final Check and Balance Confirmation  </h3> 
<ul> 
<li>   With the compensating weight attached, operate the rotor and assess the level of any residual vibration.  </li> 
<li>  The balancing procedure is finished if the remaining vibration is within the permissible limits specified in ISO 1940.  </li> 
<li>   If the vibration level remains high, repeat the process with further weight adjustments.    </li> 
</ul> 
 
<h3> Creating a Balancing Report  </h3> 
<ul> 
<li>  The program stores the balancing data, allowing you to generate and print a comprehensive report including vibration measurements, corrective weight details, and its angular placement.  </li> 
</ul> 
 
<h3> Final Recommendations  </h3> 
<ul> 
<li>   Double-check that all weights and sensors are securely fastened.    </li> 
<li>   Check that the rotor's rotation is smooth and free from undue noise or vibration.  </li> 
<li>   If the rotor operates within a larger assembly, check the functionality and interplay of all interconnected parts.  </li> 
</ul> 
 
<p>  Following this procedure enables accurate balancing, minimizes vibration, and prolongs the service life of the equipment.  </p> 
 
 
 
 
Instagram: https://www.instagram.com/vibromera_ou/ 
Youtube : https://youtu.be/guA6XJ-ArZM?si=vmkuX7RILzKBl0zL  
Our website about  <a href="https://vibromera.eu  
"> Vibration transducer </a> 
Machinio: https://www.machinio.com/listings/98380186-portable-balancer-vibration-analyzer-balanset-1a-full-kit-in-portugal 
Facebook: https://www.facebook.com/marketplace/item/350151228150722 
 
https://thebookpage.com/story2150359/hassle-free-balancing-introducing-the-new-balanset-device

-- 
This is a notification that a contact form was submitted on your website (Thamil Kathir https://thamilkathir.com).


--1739919702-eximdsn-1216622677--